rrTV-PHOTO   New HD TV
HOME   rrTV-PHOTO   GALLERIES   MY GALLERY   HELP-FAQ
myHOME PM pmRR MEMBERS 647 ONLINE 19 EVENTS SEARCH REGISTER  START HERE
 
1 page354 viewsPOST REPLY
Advantage Hobby . Revolution Models . CarbonXtreme

.
.
e-Electric Motors & Controllers > Motor wires section for 40 Amp not enough
 
 
franpla
Heliman
Location: Spain

Hello,
I have an ACTRO 24-5 and in the Operating instructions I can read that max operation current for good operation is 40 A. But the wires that come with the motor are 2.5 mm...I think not enough for 40 A.
Can anybody solve this question?
May be I am in a mistake but i can not understand it

Thank you very much
05-31-2004 Over year old.
 
 
Doug
Elite Veteran
Location: Naples Florida....

Check this out
http://www.powerstream.com/Wire_Size.htm

My read is that for the short runs involved it is adequate

First member of Member of Bearings Anonymous
05-31-2004 Over year old.
 
 
franpla
Heliman
Location: Spain

Section

Thank you
If my diammeter is 2.5 mm it means I have a section of about 5 square mm, and lloking to this table (if i am looking correctly) this cooper wire supports 15 amp...Less than 37 Amp that consumes the Actro motor.

Am I Right?
Thank you.
05-31-2004 Over year old.
 
 
Doug
Elite Veteran
Location: Naples Florida....

For short runs it would be from 47 to 51 amps

First member of Member of Bearings Anonymous
05-31-2004 Over year old.
 
 